Utilities still buy most of the US medium voltage switchgear market. But no customer group is growing faster than data centers, and they are changing what kind of switchgear gets bought.
The US medium voltage (MV) switchgear market is worth about $4.9 billion in 2026. Utility distribution remains by far the largest segment, accounting for nearly half of revenue. But the growth story belongs to data centers.
PTR’s analysis shows data-center spending on MV switchgear nearly doubling between 2026 and 2030, growing about three times faster than the market overall.
Why data centers need so much MV switchgear
A hyperscale campus is, electrically, a small utility. Power arrives at high voltage, steps down to medium voltage, typically 13.8 kV or 34.5 kV, and is distributed across the site through MV switchgear before reaching transformers, UPS systems and server halls. Every new building, power block and redundancy path adds switchgear.
Three features of data-center design push demand up further:
- Redundancy: N+1 and 2N architectures duplicate distribution paths, multiplying the switchgear per megawatt.
- Speed: developers favor compact, modular and quickly deployable equipment, often prefabricated in power skids and e-houses.
- Reliability: sealed, low-maintenance designs that keep running with minimal intervention are preferred over equipment that needs frequent servicing.
Why GIS benefits most
Those requirements favor gas-insulated switchgear (GIS). It is compact, sealed against dust and moisture, and suited to high-reliability indoor installations. Data centers take a rising share of US GIS demand through 2030.
It is one of several reasons GIS revenue grows faster than air-insulated switchgear (AIS) through 2030. AIS remains the larger market, anchored by utility distribution and industrial plants, but the mix is shifting.
What it means for suppliers
Data-center buyers behave differently from utilities. Utilities buy through approved vendor lists and long-standing framework relationships. Data-center developers and their EPCs prioritize delivery speed, footprint and standardized, repeatable designs, and they are more open to suppliers that can meet those needs.
That makes data centers one of the few segments where newer suppliers can compete against entrenched incumbents. It also raises the stakes on supply: MV switchgear lead times remain longer than before the pandemic, around 20-25 weeks for AIS and 25-30 weeks for GIS, and only 10-15% of GIS sold in the US is produced domestically.
What this means
- For OEMs: data-center demand rewards compact GIS portfolios, modular and prefabricated solutions, and the capacity to deliver repeat designs at speed.
- For developers and EPCs: switchgear belongs on the critical path; standardizing designs across campuses shortens procurement.
- For component suppliers: vacuum interrupters, protection relays and sensors for compact GIS are a growing niche.
About the data. Figures in this article come from PTR’s US Medium Voltage Switchgear Market Report 2024-2030, which sizes the market by insulation type, primary and secondary switchgear, voltage segment and vertical, with cabinet prices, market shares and supplier profiles. Request a sample at sales@ptr.inc.
Medium Voltage Switchgear Service Overview
The research presented in this article is from PTR's Medium Voltage Switchgear market research. For information about this service please submit a request shown below.
Europe: +49-89-12250950
Americas: +1 408-604-0522
Japan: +81-80-7808-1378
GCC/Rest of APAC: +971-58-1602441
More About our: Medium Voltage Switchgear Market Analysis
Recent Insights
SF₆-Free MV Switchgear: California and New York Have Set the Clock
For decades, SF₆ has been the default insulating gas in medium voltage GIS. In two of the largest US states, that era now has an end date. Sulfur hexafluoride (SF₆) is an exceptionally effective insulating gas, and one of the most potent greenhouse gases known. State...
Wildfire Risk Is Changing How Western US Utilities Switch Their Feeders
When a spark can start a wildfire, the way a utility opens and closes a circuit becomes a safety decision. In the West, that is reshaping the equipment on overhead feeders. Across California, Oregon, Colorado and other fire-prone states, utilities have launched...
Manual Today, Motorized Tomorrow: Why the Air Break Switch Still Has a Place in the Smart Grid
Smart-grid headlines focus on reclosers, sensors and software. Out on the poles, one of the oldest devices on the network is quietly being upgraded rather than replaced. The three-phase ganged air break switch is one of the most familiar pieces of equipment in...
SF₆-Free MV Switchgear: California and New York Have Set the Clock
For decades, SF₆ has been the default insulating gas in medium voltage GIS. In two of the largest US states, that era now has an end date. Sulfur hexafluoride (SF₆) is an exceptionally effective insulating gas, and one of the most potent greenhouse gases known. State...
Wildfire Risk Is Changing How Western US Utilities Switch Their Feeders
When a spark can start a wildfire, the way a utility opens and closes a circuit becomes a safety decision. In the West, that is reshaping the equipment on overhead feeders. Across California, Oregon, Colorado and other fire-prone states, utilities have launched...
Manual Today, Motorized Tomorrow: Why the Air Break Switch Still Has a Place in the Smart Grid
Smart-grid headlines focus on reclosers, sensors and software. Out on the poles, one of the oldest devices on the network is quietly being upgraded rather than replaced. The three-phase ganged air break switch is one of the most familiar pieces of equipment in...
Substations in a Box: Why Utilities Are Turning to E-Houses
Building a substation used to mean months of site work. More utilities now order the electrical building from a factory, tested and ready to connect. An e-house is a prefabricated, transportable building that houses medium- and low-voltage switchgear, protection and...