Wildfire Risk Is Changing How Western US Utilities Switch Their Feeders

Written By: admin
Published On: November 19, 2026

Article

Wildfire Risk Is Changing How Western US Utilities Switch Their Feeders

Written By: admin
Published On: November 19, 2026

When a spark can start a wildfire, the way a utility opens and closes a circuit becomes a safety decision. In the West, that is reshaping the equipment on overhead feeders.

Across California, Oregon, Colorado and other fire-prone states, utilities have launched aggressive wildfire-hardening programs. Much of the attention goes to vegetation management and undergrounding, but the overhead feeder itself is changing too: how it is divided into sections, how faults are isolated, and what equipment does the switching.

The problem with an open arc

Air break switches have long been the standard way to sectionalize overhead distribution lines. They are simple, durable and inexpensive. But when a motorized air break switch operates under load, it can draw a visible arc. In dry, windy, high-risk areas, that arc is an ignition hazard.

California has restricted the use of open-arc motorized switches. Utilities there and in other Western states are shifting switching duty in high-risk zones to arc-free devices, typically vacuum reclosers, that can isolate faults and operate remotely without exposing an arc.

What utilities are doing instead

  • More sectionalizing points: wildfire programs focus on dividing networks into smaller sections so that faults and preventive shutoffs affect fewer customers and a smaller geographic area.
  • Automated fault isolation: remote and automatic switching reduces the need for crews to patrol and operate devices in dangerous conditions.
  • Fire-season settings: newer reclosers can be programmed for fire season, and pulse reclosing or low-energy fault testing checks a line before re-energizing it, reducing the energy released into a fault.

Regulators and planners are reinforcing the shift. Puget Sound Energy’s 2025 Wildfire Mitigation Plan and the US Department of Energy’s 2024 resilience guidance both prioritize electronic reclosers for hazard zones.

Where the air break switch still fits

None of this ends the air break switch. On rural and semi-urban feeders, where automated reclosers are not economical, gang-operated air break switches remain the standard.

The result is a more segmented market. In high-risk areas, switching duty moves to arc-free automated devices. Elsewhere, air break switches continue to be specified, increasingly with motor operators and remote control, as a lower-cost route to automation.

What this means

  • For utilities: wildfire risk maps now shape equipment standards. Switching device choice should be mapped to hazard zone, not set network-wide.
  • For manufacturers: demand splits by geography. Arc-free automation wins in hazard zones, while durable, automation-ready air break switches hold their ground elsewhere.
  • For component suppliers: motor operators, controls and communications are needed on both sides of that split.

About the data. PTR’s US & Canada Recloser Market Report 2024-2030 sizes the US and Canadian recloser market to 2030 in units, revenue and installed base by voltage band, and covers demand drivers including wildfire mitigation and technology trends such as fire-season settings and pulse reclosing. Request a sample at sales@ptr.inc.

Medium Voltage Switchgear Service Overview 

The research presented in this article is from PTR's Medium Voltage Switchgear market research. For information about this service please submit a request shown below.

Contact Us

Europe: +49-89-12250950 

Americas: +1 408-604-0522

Japan: +81-80-7808-1378 

GCC/Rest of APAC: +971-58-1602441 

Recent Insights

SF₆-Free MV Switchgear: California and New York Have Set the Clock

SF₆-Free MV Switchgear: California and New York Have Set the Clock

For decades, SF₆ has been the default insulating gas in medium voltage GIS. In two of the largest US states, that era now has an end date. Sulfur hexafluoride (SF₆) is an exceptionally effective insulating gas, and one of the most potent greenhouse gases known. State...

SF₆-Free MV Switchgear: California and New York Have Set the Clock

SF₆-Free MV Switchgear: California and New York Have Set the Clock

For decades, SF₆ has been the default insulating gas in medium voltage GIS. In two of the largest US states, that era now has an end date. Sulfur hexafluoride (SF₆) is an exceptionally effective insulating gas, and one of the most potent greenhouse gases known. State...

Substations in a Box: Why Utilities Are Turning to E-Houses

Substations in a Box: Why Utilities Are Turning to E-Houses

Building a substation used to mean months of site work. More utilities now order the electrical building from a factory, tested and ready to connect. An e-house is a prefabricated, transportable building that houses medium- and low-voltage switchgear, protection and...